Energy Meter VM-3P75CT Single + 3-Phase
The Victron VM-3P75CT energy meter is a standard device to measure the power and energy of single- and three-phase applications and calculates each phase’s power values and broadcasts this over VE.Can or Ethernet with a high rate. It has built-in Ethernet and VE.Can ports for connecting to a GX device and the split-core current transformers enable easy and quick installation without modifying existing wiring.
The energy meter works out of the box (the firmware may need to be updated; details can be found in the Firmware Updates chapter) as a grid meter for systems with a MultiPlus and Quattro. Configuration (via VictronConnect) is only required for changing the role and manual IP configuration, rather than the default DHCP. Its data is displayed on a GX device such as the Cerbo GX or Ekrano GX, as well as in VictronConnect and the VRM Portal.
Specifications:
- Voltage connection: Direct
- Input voltage range L-N: 85 to 265VAC
- Input voltage range L-L:150 to 460VAC
- Frequency: 50/60Hz
- Current connection: Via current transformers (included – wire length 640mm (25.2in)
- Rated current: 75A
- VE.Can communication port: Two RJ45 connectors (VE.Can terminators included)
- Ethernet communication port: One RJ45 connector, Modbus UDP
- Refresh rate: 100ms
- Type: Self-power supply via L1-N
- Switch or circuit breaker: Required as a means of a disconnecting device – not included
- External fuse [1]: Required in the neutral conductor – 500mA, not included
- Consumption: 1.45W / 3.1VA
- Frequency: 50/60Hz
- Material & Color: Polycarbonate, blue (RAL5012)
- Voltage connection: Screw terminals 0.25 – 1.5mm2 (24 – 16AWG)
- Current transformer connection: Pluggable screw terminals (included)
- Protection category: IP20
- Weight: 370g (including packaging)
- Dimensions: 90 x 71 x 59mm (3.5 x 2.8 x 2.3in)
- Indoor/outdoor usage: Indoor only
- Operating temperature: From -10 to +55 °C
- Storage temperature: From -20 to +70 °C
- Relative humidity: <90% non-condensing
- Altitude: 2000m (6562ft)
- Mains supply voltage fluctuations: ±0.1Vin
- Overvoltage category: Cat. III
- Pollution degree: 2
What’s In The Box?
- Victron VM-3P75CT with 3 input terminal blocks
- 3x Split-core current transformer, wired ready for connection
- Wire length: 640mm (25.3″)
- VE.Can terminators (2-pieces)
Please contact your dealer for any returns, repairs or support issues related to this product.
Quick Guide (pdf)

![Blue Sea 8242 Shunt Adapter for DC Digital Ammeter [8242]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8242-shunt-adapter-dc-digital-ammeter-8242.webp)
![Blue Sea 8244 AC Analog Micro Voltmeter - 2" Face, 0-150 Volts AC [8244]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8244-ac-analog-micro-voltmeter-2-face-0-150-volts-ac-8244.webp)
![Blue Sea 8028 DC Analog Micro Voltmeter - 2" Face, 8-16 Volts DC [8028]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8028-dc-analog-micro-voltmeter-2-face-8-16-volts-dc-8028.webp)
![Blue Sea 8255 Digital Meter Shunt 500A/50mV [8255]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8255-digital-meter-shunt-500a-50mv-8255.webp)
![BEP DC Color Systems Monitor (DCSM) - No Shunt [80-600-0022-00]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/bep-dc-color-systems-monitor-dcsm-no-shunt-80-600-0022-00.webp)
![Blue Sea 8256 AC Current Transformer [8256]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8256-ac-current-transformer-8256.webp)
![Blue Sea 8252 DC Zero Center Analog Ammeter - 2-3/4" Face, 50-0-50 Amperes DC [8252]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8252-dc-zero-center-analog-ammeter-2-3-4-face-50-0-50-amperes-dc-8252.webp)
![Blue Sea 8253 DC Zero Center Analog Ammeter - 2-3/4" Face, 100-0-100 Amperes DC [8253]](https://www.boataccessorydepot.com/wp-content/uploads/2026/10/blue-sea-8253-dc-zero-center-analog-ammeter-2-3-4-face-100-0-100-amperes-dc-8253.webp)